Some moving companies will only go so far to transport your mobile home and leave it to you to find a plumber electrician etc.
Mobile home meter pole installation.
Overhead installations the metering pole must be a minimum of 17 ft class 5 pole set at least 4 ft deep so that it will be of sufficient height and stability to provide service drop clearances as shown on page 31.
All meter sockets shall be mounted in a manner that allows meters to be inserted and withdrawn.
Pole with meter base and 240v 200 amp disconnect.
With that said try finding a moving company that can will handle all aspects of installation.
Street 36 min.
Position pedestal so that electric meter is facing away from mobile home towards right of way.
Alternate location for pedestal.
The mhm200p is 200 amp unit and is designed with ample width to ensure plenty of room for wire bending and an easier installation.
Pvc conduit to the home gray schedule 40 or.
Meter base mounted on exterior wall of house or mobile manufactured home.
Eaton s versatile mobile home panels have a user friendly design that allows for a faster cleaner installation.
Fasten each strap with two galvanized 1 4 by 2 1 2 lag screws.
Older mobile homes were manufactured to provide 100 amp electrical service.
It is also suitable for service entrance equipment.
If metallic weather head is used with pvc conduit it must have a bonding ground.
To do the rest of the work.
Three metal conduit straps minimum one near top one mid way and one within a foot of the meter socket.
Pole with 480v 30 amp disconnect.
When one of these mobile homes need a wiring overhaul it is best to upgrade to 200 amp service.
The pole must be treated and be at least a class 7 round or 6 x 6 square and have a minimum of 14 5 feet above the ground.
Overhead service to.
Overhead service to mobile home.
This does not require you to replace every foot of wire in the mobile home.
Install on side of pole opposite service drop.
25 foot meter poles and fused disconnect poles.
See below for our assembly guide for meter pole installation.
Trench depth shall be 30 inches minimum with or without gas service and greater if joint with a gas main.
Two ft of conduit above pole.
Position pedestal so that electric meter is facing away from mobile home.
Use 2 0 thw hotlegs with minimum 18 tails for connection tvec will spot all mobile home poles 1 neutral stranded copper meter base unbroken for connection galvanized steeples or wire holding.
Hooking the home up to sewer lines and electric meters is not a simple diy project.
Metering installations for mobile homes or mobile home parks.